Discuss a project

0,4kVLow voltage

Low-voltage switchgear assemblies, distribution boards and reactive power compensation units — manufacturing, installation and commissioning.

ShchO-99 panels in the BIONIKA workshop: busbars with phase colour coding

Applications

  • Industrial buildings
  • Shopping centres and offices
  • Residential buildings
  • LV switchgear of substations

Equipment

  • KTP: Packaged transformer substations
    KTP in the BIONIKA workshop — photo 1
    KTP in the BIONIKA workshop — photo 2
    KTP in the BIONIKA workshop — photo 3

    Photos from the BIONIKA workshop

    6(10)/0.4 kV

    KTP

    Packaged transformer substations

    Packaged 6(10)/0.4 kV transformer substations: the high-voltage section, power transformer and 0.4 kV distribution board in one factory-built enclosure. Made in the workshop and installed on site.

    Transformer rating
    25–2500 kVA
    HV / LV voltage
    6 or 10 / 0.4 kV
    Scheme
    dead-end or pass-through; one or two transformers
    Design
    outdoor (U1) or indoor installation
  • Urban packaged transformer substation

    Request a quote
    GKTP: Urban packaged transformer substation — renderingRendering
    GKTP in the BIONIKA workshop — photo 1
    GKTP in the BIONIKA workshop — photo 2
    GKTP in the BIONIKA workshop — photo 3

    Photos from the BIONIKA workshop

    6(10)/0.4 kV

    GKTP

    Urban packaged transformer substation

    Urban packaged transformer substations 6(10)/0.4 kV in a steel enclosure on a foundation: they supply residential buildings, public buildings and small businesses. Inside: a high-voltage compartment, a power transformer and a 0.4 kV board with outgoing lines.

    Transformer rating
    25–1000 kVA
    HV / LV voltage
    6 or 10 / 0.4 kV
    Scheme
    dead-end or pass-through, one transformer
    Design
    outdoor installation, U1; cable entries
  • Double urban packaged transformer substation

    Request a quote
    2GKTP: Double urban packaged transformer substation — renderingRendering
    2GKTP in the BIONIKA workshop — photo 1
    2GKTP in the BIONIKA workshop — photo 2
    2GKTP in the BIONIKA workshop — photo 3

    Photos from the BIONIKA workshop

    6(10)/0.4 kV

    2GKTP

    Double urban packaged transformer substation

    Urban 6(10)/0.4 kV substations with two power transformers in a steel enclosure: if one transformer fails, the other takes the load. For consumers who need a backup supply: residential complexes, hospitals, retail and public buildings.

    Transformer ratings
    2 × 250–1000 kVA
    HV / LV voltage
    6 or 10 / 0.4 kV
    Scheme
    dead-end or pass-through; two 0.4 kV bus sections
    Design
    outdoor installation, U1; cable entries
  • Pole-mounted packaged transformer substation

    Request a quote
    KTPS: Pole-mounted packaged transformer substation — renderingRendering

    6(10)/0.4 kV

    KTPS

    Pole-mounted packaged transformer substation

    Compact outdoor substation for 6–10 kV overhead lines: a high-voltage entry with arresters, a power transformer and a 0.4 kV cabinet in one unit. Supplies villages, farms, pumping stations, construction sites and small production facilities.

    Transformer rating
    25–250 kVA
    HV / LV voltage
    6 or 10 / 0.4 kV
    Scheme
    dead-end, HV overhead entry
    Design
    outdoor installation, U1
  • Distribution board panels (LV switchgear)

    Request a quote
    ShchO-99: Distribution board panels (LV switchgear) — renderingRendering
    ShchO-99 in the BIONIKA workshop — photo 1
    ShchO-99 in the BIONIKA workshop — photo 2
    ShchO-99 in the BIONIKA workshop — photo 3

    Photos from the BIONIKA workshop

    0.4 kV

    ShchO-99

    Distribution board panels (LV switchgear)

    Single-sided service panels for 0.4 kV distribution boards in solidly earthed networks: incoming, feeder and section panels. They receive and distribute power and protect lines against overload and short circuit. Inside: busbars with phase colour coding, circuit breakers, switch-disconnectors, current transformers and metering.

    Rated voltage
    380/220 V, 50 Hz
    Devices
    circuit breakers, switch-disconnectors, fuses, current transformers, metering
    Design
    indoor installation, U3; single-sided service
  • Reactive power compensation units

    Request a quote
    UKRM: Reactive power compensation units — renderingRendering
    UKRM in the BIONIKA workshop — photo 1
    UKRM in the BIONIKA workshop — photo 2
    UKRM in the BIONIKA workshop — photo 3

    Photos from the BIONIKA workshop

    0.4–0.69 kV and 6–10 kV

    UKRM

    Reactive power compensation units

    Capacitor banks for reactive power compensation in 0.4–0.69 kV and 6–10 kV networks. NOVAR / DCRL / DCRG controllers automatically switch the number of connected capacitors and keep cos φ constant: fewer penalties from the power supply company and higher load capacity of lines and transformers.

    Network voltage
    400 / 440 / 525 / 690 V; 6 and 10 kV
    Controllers
    NOVAR / DCRL / DCRG
    Rating
    calculated for the site; typical range from 10 to 1000 kvar and above
    Design
    indoor (U3) or outdoor (U1) installation

Technical capabilities

Completed
100+ sites
Types of work
Manufacturing, installation, commissioning, testing
Permits
Permits and licences for work in power networks from 0.4 to 500 kV

Projects

100+ sites completed at 0,4 kV. Describe your site and our specialists will estimate the scope of work.

Discuss a project

Technical documentation

  • Questionnairein preparation
  • Technical cataloguein preparation
  • Standard diagramsin preparation

A 0,4 kV project?

Send us the technical specification — BIONIKA specialists will assess the project and propose a solution.